ExposurePairerConfig#

class lsst.ts.wep.task.ExposurePairerConfig(*args, **kw)#

Bases: Config

Attributes Summary

doOverrideSeparation

Whether to override expected intra-focal to focal separation (bool, default False)

forceUniquePairs

If True, force each extra exposure to be paired with a unique intra exposure.

groupingThreshold

Threshold for assigning visit to intra/extra/focal group as a fraction of the expected intra-focal to focal separation.

ignoreThresholds

If True, ignore time, pointing, and rotation thresholds.

overrideSeparation

Expected extra-focal to focal separation (mm).

pointingThreshold

Maximum pointing difference between paired intra- and extra-focal exposures (arcsec) (float, default 60)

rotationThreshold

Maximum rotator angle difference between paired intra- and extra-focal exposures (deg) (float, default 1.0)

timeThreshold

Maximum time difference between paired intra- and extra-focal exposures (s) (float, default 300)

Attributes Documentation

doOverrideSeparation: Field#

Whether to override expected intra-focal to focal separation (bool, default False)

forceUniquePairs: Field#

If True, force each extra exposure to be paired with a unique intra exposure. (bool, default True)

groupingThreshold: Field#

Threshold for assigning visit to intra/extra/focal group as a fraction of the expected intra-focal to focal separation. (float, default 0.1)

ignoreThresholds: Field#

If True, ignore time, pointing, and rotation thresholds. Useful when grouping by exposure.group (bool, default False)

overrideSeparation: Field#

Expected extra-focal to focal separation (mm). Note that this is signed such that a positive value means an extra-focal exposure has a greater focusZ value than an intra-focal exposure. (float, default 1.5)

pointingThreshold: Field#

Maximum pointing difference between paired intra- and extra-focal exposures (arcsec) (float, default 60)

rotationThreshold: Field#

Maximum rotator angle difference between paired intra- and extra-focal exposures (deg) (float, default 1.0)

timeThreshold: Field#

Maximum time difference between paired intra- and extra-focal exposures (s) (float, default 300)